Echo Research and Practice (Sep 2023)
Intraprocedural versus next day transthoracic echocardiography following minimalist transfemoral TAVI
Abstract
Abstract Background Routine pre-discharge echocardiography (ECHO) is recommended post transcatheter aortic valve implantation (TAVI) as a baseline for future comparison. However, there is no clear guidance on the optimal timing of this study. Aim The purpose of this retrospective study was to investigate the safety and work-force efficiency of intraprocedural same-day ECHO versus next-day ECHO, following transfemoral TAVI. Methods and results In this retrospective study 100 consecutive patients who underwent intraprocedural ECHO only were compared with 100 consecutive patients undergoing both intraprocedural and routine next-day ECHO following elective transfemoral TAVI. All patients received the Sapien 3/Ultra transcatheter heart valve and were treated with a minimalist procedure with conscious sedation. The composite of in-hospital mortality, urgent ECHO and new tamponade after leaving the cath lab and before discharge was not different between the two groups (4 vs. 4%, P = 1). There was no paravalvular leak more than mild in any of the cases. Length of stay was similar (1 day). Conclusions Intraprocedural post-TAVI ECHO appears as safe as next day pre-discharge ECHO and obviates the need for a routine next day study, thereby reducing burden on echocardiography services and allows better utilisation of resources.