EPJ Web of Conferences (Jan 2015)
Evaluation of pump characteristic from measurement of fast deceleration
Abstract
Article describes an experiment where a pump connected to the simple hydraulic circuit is decelerated. Since the deceleration is fast enough the operating point of the machine moves from the initial steady position to the breaking zone, turbine zone and back to the new steady position. A dependence of the specific energy and the torque on the flow rate was evaluated from the measurement of the input and output pressure, torque and rotational speed recorded during the deceleration. Obtained characteristic is much wider than curves obtained from regular measurement of steady state.