Медицинский вестник Юга России (Jun 2014)

DIAGNOSTIC CHARACTERISTICS OF A LATEX ANTIGEN HELICOBACTER TEST-SYSTEM

  • E. A. Bereznyak,
  • L. M. Verkina,
  • Yu. L. Bereznyak,
  • I. R. Simonova

DOI
https://doi.org/10.21886/2219-8075-2014-2-41-44
Journal volume & issue
Vol. 0, no. 2
pp. 41 – 44

Abstract

Read online

Purpose: The study of operation diagnostic characteristics of a newly constructed helicobacter test-system which is designed to determine the total antibodies in the blood serum in volumetric agglomeration reaction.Materials and methods: Blood sera of 224 gastroenterological patients were studied with the help of diagnostic system constructed. Commercial immune-enzyme blood assay systems were used to be the referent method.Results: Diagnostic operation characteristics of a latex antigen helicobacter test-system were determined with the help of referent serological diagnostic methods. At the cut-off point 1:160 the sensitivity, specificity and diagnostic effectiveness are 94,9%, 79,3% и 88,2%, respectively.Summary: The cut-off point 1:160 is shown to be used as a diagnostic threshold.