E3S Web of Conferences (Jan 2019)

Development of zero energy flexible unit with no Infrastructure for disaster and disaster response

  • Park Beungyong,
  • Cho Jinkyun,
  • Jeong Yongdae,
  • Lee Sangmoon

DOI
https://doi.org/10.1051/e3sconf/201911106003
Journal volume & issue
Vol. 111
p. 06003

Abstract

Read online

In this paper a new kind of unit-prefabricated building is shown. The unit-prefabricated buildings are made up living unit, energy unit, water unit. The each unit was adapted new combine structure function as a high flexible design type. Moreover the design trend implemented the energy insulation, Solar PV panels, Energy storage system which are maintained for zero energy buildings. We made a prototype for zero energy flexible residential unit. The first step, we was evaluated physical performance and living environment, insulation, airtightness, thermal environmental, acoustic performance. The second step we was evaluated energy performance building to design heating and cooling system to combined PV, ESS system in the different plan type, and climate. As a results, The insulation performance wall was 0.18 W/(m2•K). The results of air-tightness was 12.13 ACH@50 (1/h). Further research we develop the structure and construction technology for zero energy flexible unit. To designed the high performance energy performance for zero energy building in the natural disaster.