Archives of Electrical Engineering (Mar 2024)

Dead time effects compensation strategy by third harmonic injection for a five-phase inverter

  • Krzysztof Łuksza,
  • Dmytro Kondratenko,
  • Arkadiusz Lewicki

DOI
https://doi.org/10.24425/aee.2024.148854
Journal volume & issue
Vol. vol. 73, no. No 1
pp. 17 – 35

Abstract

Read online

This paper proposes a method for compensation of dead-time effects for a fivephase inverter. In the proposed method an additional control subsystem was added to the field-oriented control (FOC) scheme in the coordinate system mapped to the third harmonic. The additional control loop operates in the fixed, orthogonal reference frame ( α - β coordinates) without the need for additional Park transformations. The purpose of this method is to minimize the dead-time effects by third harmonic injection in two modes of operation of the FOC control system: with sinusoidal supply and with trapezoidal supply. The effectiveness of the proposed control method was verified experimentally on a laboratory setup with a prototype five-phase interior permanent magnet synchronous machine (IPMSM). All experimental results were presented and discussed in the following paper.

Keywords