JMIR Rehabilitation and Assistive Technologies (Aug 2024)

Preliminary Validity and Acceptability of Motion Tape for Measuring Low Back Movement: Mixed Methods Study

  • Audrey Lee,
  • Elijah Wyckoff,
  • Emilia Farcas,
  • Job Godino,
  • Kevin Patrick,
  • Spencer Spiegel,
  • Rose Yu,
  • Arun Kumar,
  • Kenneth J Loh,
  • Sara Gombatto

DOI
https://doi.org/10.2196/57953
Journal volume & issue
Vol. 11
p. e57953

Abstract

Read online

BackgroundLow back pain (LBP) is a significant public health problem that can result in physical disability and financial burden for the individual and society. Physical therapy is effective for managing LBP and includes evaluation of posture and movement, interventions directed at modifying posture and movement, and prescription of exercises. However, physical therapists have limited tools for objective evaluation of low back posture and movement and monitoring of exercises, and this evaluation is limited to the time frame of a clinical encounter. There is a need for a valid tool that can be used to evaluate low back posture and movement and monitor exercises outside the clinic. To address this need, a fabric-based, wearable sensor, Motion Tape (MT), was developed and adapted for a low back use case. MT is a low-profile, disposable, self-adhesive, skin-strain sensor developed by spray coating piezoresistive graphene nanocomposites directly onto commercial kinesiology tape. ObjectiveThe objectives of this study were to (1) validate MT for measuring low back posture and movement and (2) assess the acceptability of MT for users. MethodsA total of 10 participants without LBP were tested. A 3D optical motion capture system was used as a reference standard to measure low back kinematics. Retroreflective markers and a matrix of MTs were placed on the low back to measure kinematics (motion capture) and strain (MT) simultaneously during low back movements in the sagittal, frontal, and axial planes. Cross-correlation coefficients were calculated to evaluate the concurrent validity of MT strain in reference motion capture kinematics during each movement. The acceptability of MT was assessed using semistructured interviews conducted with each participant after laboratory testing. Interview data were analyzed using rapid qualitative analysis to identify themes and subthemes of user acceptability. ResultsVisual inspection of concurrent MT strain and kinematics of the low back indicated that MT can distinguish between different movement directions. Cross-correlation coefficients between MT strain and motion capture kinematics ranged from –0.915 to 0.983, and the strength of the correlations varied across MT placements and low back movement directions. Regarding user acceptability, participants expressed enthusiasm toward MT and believed that it would be helpful for remote interventions for LBP but provided suggestions for improvement. ConclusionsMT was able to distinguish between different low back movements, and most MTs demonstrated moderate to high correlation with motion capture kinematics. This preliminary laboratory validation of MT provides a basis for future device improvements, which will also involve testing in a free-living environment. Overall, users found MT acceptable for use in physical therapy for managing LBP.