Nuclear Materials and Energy (May 2019)

Designing high efficiency glow discharge cleaning systems

  • A. Canton,
  • R. Cavazzana,
  • L. Grando,
  • M. Spolaore,
  • M. Zuin

Journal volume & issue
Vol. 19
pp. 468 – 472

Abstract

Read online

In this paper we present our studies about the choices of anode design and operational regime in order to get high efficiency glow discharge cleaning of the first wall of a fusion device. We analyzed a database of toroidal and poloidal profiles of the ion current density at the wall, measured by electrostatic probes embedded in RFX-mod first wall tiles, taken in different configurations. The ion current at the wall, both global and local, is in fact strictly connected to the cleaning efficiency, since during glow discharge the wall is physically sputtered by the ions. We found that small size anodes and high in-vessel pressure lead to the peaking of the current profile around the anodes locations, and we experimentally characterized this effect. Instead, we found that anode radial position in the poloidal section has negligible effect on current density profile, even when the anodes are placed at the first wall. Finally, the most convenient operational regime, in terms of pressure and current, has been proposed. Keywords: RFX-mod, Glow discharge, Wall cleaning, Ion current profile, Anode design