Medžiagotyra (Dec 2013)

Broadband Electromagnetic Emission from PZT Ferroelectric Ceramics after Shock Loading

  • Fiodoras ANISIMOVAS,
  • Steponas AŠMONTAS,
  • Oleg KIPRIJANOVIČ,
  • Andrius MANEIKIS,
  • Bonifacas VENGALIS

DOI
https://doi.org/10.5755/j01.ms.19.4.3137
Journal volume & issue
Vol. 19, no. 4
pp. 433 – 437

Abstract

Read online

It was experimentally registered pulsed electromagnetic (EM) radiation in frequency range higher than television one using wideband horns with coaxial and waveguide outputs. The EM radiation was received during shock loading of lead zirconate titanate (PZT) ceramics cylinders in conventional piezoelectric ignition mechanisms. Digital oscilloscope allows registering whole series of EM pulses and each pulse from the series transmitted from horn antenna of (1 – 18) GHz operating band frequencies. There is (1 – 4) ms delay between the shock and the first pulse of the series. Duration of the series is about (3 – 4) ms. The PZT cylinders were cleaved along their axes and the surfaces formed in the process were investigated by scanning electron microscope. It was concluded that from electrical point of view PZT ceramics contain interacting subsystems. It was found that EM radiation spectrum of pulse detected by waveguide detector heads has harmonics reaching 80 GHz. Presence of harmonics higher than 20 GHz indicates on radiation due to deceleration of electrons emitted during the switching. The EM pulses in the series appear randomly and have different amplitudes which partly confirmed thesis on independent switching dynamics of small volumes governed by a local electric field.DOI: http://dx.doi.org/10.5755/j01.ms.19.4.3137

Keywords