Actuators (Feb 2014)

Energetic and Peak Power Advantages of Series Elastic Actuators in an Actuated Prosthetic Leg for Walking and Running

  • Martin Grimmer,
  • Mahdy Eslamy,
  • André Seyfarth

DOI
https://doi.org/10.3390/act3010001
Journal volume & issue
Vol. 3, no. 1
pp. 1 – 19

Abstract

Read online

A monoarticular series elastic actuator (SEA) reduces energetic and peak power requirements compared to a direct drive (DD) in active prosthetic ankle-foot design. Simulation studies have shown that similar advantages are possible for the knee joint. The aims of this paper were to investigate the advantages of a monoarticular SEA-driven hip joint and to quantify the energetic benefit of an SEA-driven leg (with monoarticular hip, knee and ankle SEAs), assuming that damping (negative power) is passively achieved. The hip SEA provided minor energetic advantages in walking (up to 29%) compared to the knee and the ankle SEA. Reductions in required peak power were observed only for speeds close to preferred walking speed (18% to 27%). No energetic advantages were found in running, where a DD achieved the best performance when optimizing for energy. Using an SEA at each leg joint in the sagittal plane reduced the positive work by 14% to 39% for walking and by 37% to 75% for running. When using an SEA instead of a DD, the contribution of the three leg joints to doing positive work changed: the knee contributed less and the hip more positive work. For monoarticular SEAs, the ankle joint motor did most of the positive work.

Keywords