BMC Medical Imaging (Mar 2024)

Evaluating the consistency in different methods for measuring left atrium diameters

  • Jun-Yan Yue,
  • Kai Ji,
  • Hai-Peng Liu,
  • Qing-Wu Wu,
  • Chang-Hua Liang,
  • Jian-Bo Gao

DOI
https://doi.org/10.1186/s12880-024-01231-6
Journal volume & issue
Vol. 24, no. 1
pp. 1 – 13

Abstract

Read online

Abstract Background The morphological information of the pulmonary vein (PV) and left atrium (LA) is of immense clinical importance for effective atrial fibrillation ablation. The aim of this study is to examine the consistency in different LA diameter measurement techniques. Methods Retrospective imaging data from 87 patients diagnosed with PV computed tomography angiography were included. The patients consisted of 50 males and 37 females, with an average age of (60.74 ± 8.70) years. Two physicians independently measured the anteroposterior diameter, long diameter, and transverse diameter of the LA using six different methods. Additionally, we recorded the post-processing time of the images. Physician 1 conducted measurements twice with a one-month interval between the measurements to assess intra-rater reliability. Using the intraclass correlation coefficient (ICC), the consistency of each LA diameter measurement by the two physicians was evaluated. We compared the differences in the LA diameter and the time consumed for measurements using different methods. This was done by employing the rank sum test of a randomized block design (Friedman M test) and the q test for pairwise comparisons among multiple relevant samples. Results (1) The consistency of the measured LA diameter by the two physicians was strong or very strong. (2) There were statistical differences in the anteroposterior diameter, long diameter, and transverse diameter of LA assessed using different methods (χ 2 = 222.28, 32.74, 293.83, P < 0.001). (3) Different methods for measuring the diameters of LA required different amounts of time (χ 2 = 333.10, P < 0.001). Conclusion The results of left atrium (LA) diameter measurements conducted by different physicians were found to be reliable. However, the LA diameters obtained through various techniques exhibited variations. It was observed that measuring LA long diameters using only the VR (volume rendering) picture was the most clinically applicable method.

Keywords