Journal of NeuroEngineering and Rehabilitation (Jun 2022)

Soft robotics and functional electrical stimulation advances for restoring hand function in people with SCI: a narrative review, clinical guidelines and future directions

  • Lucas R. L. Cardoso,
  • Vanesa Bochkezanian,
  • Arturo Forner-Cordero,
  • Alejandro Melendez-Calderon,
  • Antonio P. L. Bo

DOI
https://doi.org/10.1186/s12984-022-01043-1
Journal volume & issue
Vol. 19, no. 1
pp. 1 – 24

Abstract

Read online

Abstract Background Recovery of hand function is crucial for the independence of people with spinal cord injury (SCI). Wearable devices based on soft robotics (SR) or functional electrical stimulation (FES) have been employed to assist the recovery of hand function both during activities of daily living (ADLs) and during therapy. However, the implementation of these wearable devices has not been compiled in a review focusing on the functional outcomes they can activate/elicit/stimulate/potentiate. This narrative review aims at providing a guide both for engineers to help in the development of new technologies and for clinicians to serve as clinical guidelines based on the available technology in order to assist and/or recover hand function in people with SCI. Methods A literature search was performed in Scopus, Pubmed and IEEE Xplore for articles involving SR devices or FES systems designed for hand therapy or assistance, published since 2010. Only studies that reported functional outcomes from individuals with SCI were selected. The final collections of both groups (SR and FES) were analysed based on the technical aspects and reported functional outcomes. Results A total of 37 out of 1101 articles were selected, 12 regarding SR and 25 involving FES devices. Most studies were limited to research prototypes, designed either for assistance or therapy. From an engineering perspective, technological improvements for home-based use such as portability, donning/doffing and the time spent with calibration were identified. From the clinician point of view, the most suitable technical features (e.g., user intent detection) and assessment tools should be determined according to the particular patient condition. A wide range of functional assessment tests were adopted, moreover, most studies used non-standardized tests. Conclusion SR and FES wearable devices are promising technologies to support hand function recovery in subjects with SCI. Technical improvements in aspects such as the user intent detection, portability or calibration as well as consistent assessment of functional outcomes were the main identified limitations. These limitations seem to be be preventing the translation into clinical practice of these technological devices created in the laboratory.

Keywords