European Journal of Medical Research (Nov 2017)

Comparative analysis of high-sensitivity cardiac troponin I and T for their association with coronary computed tomography-assessed calcium scoring represented by the Agatston score

  • Jonas Rusnak,
  • Michael Behnes,
  • Thomas Henzler,
  • Nadine Reckord,
  • Nils Vogler,
  • Mathias Meyer,
  • Ursula Hoffmann,
  • Michele Natale,
  • Julia Hoffmann,
  • Sonja Hamed,
  • Kathrin Weidner,
  • Siegfried Lang,
  • Agnibh Mukherji,
  • Holger Haubenreisser,
  • Stefan O. Schoenberg,
  • Martin Borggrefe,
  • Thomas Bertsch,
  • Ibrahim Akin

DOI
https://doi.org/10.1186/s40001-017-0290-9
Journal volume & issue
Vol. 22, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background This study evaluates the association between high-sensitivity cardiac troponin I (hs-cTnI) and T (hs-cTnT) and coronary calcium concentration (CAC) detected by coronary computed tomography (CCT) and evaluated with the Agatston score in patients with suspected coronary artery disease (CAD). Methods Patients undergoing CCT during routine clinical care were enrolled prospectively. CCT was indicated for patients with a low to intermediate pretest probability for CAD. Within 24 h of CCT examination, peripheral blood samples were taken to measure cardiac biomarkers hs-cTnI and hs-cTnT. Results A total of 76 patients were enrolled including 38% without detectable CAC, 36% with an Agatston score from 1 to 100, 17% from 101 to 400, and 9% with values ≥ 400. hs-cTnI was increasing alongside Agatston score and was able to differentiate between different groups of Agatston scores. Both hs-cTn discriminated values greater than 100 (hs-cTnI, AUC = 0.663; p = 0.032; hs-cTnT, AUC = 0.650; p = 0.048). In univariate and multivariate logistic regression models, hs-cTnT and hs-cTnI were significantly associated with increased Agatston scores. Patients with hs-cTnT ≥ 0.02 µg/l and hs-cTnI ≥ 5.5 ng/l were more likely to reveal values ≥ 400 (hs-cTnT; OR = 13.4; 95% CI 1.545–116.233; p = 0.019; hs-cTnI; OR = 8.8; 95% CI 1.183–65.475; p = 0.034). Conclusion The present study shows that the Agatston score was significantly correlated with hs cardiac troponins, both in univariable and multivariable linear regression models. Hs-cTnI is able to discriminate between different Agatston values. The present results might reveal potential cut-off values for hs cardiac troponins regarding different Agatston values. Trial registration Cardiovascular Imaging and Biomarker Analyses (CIBER), NCT03074253 https://clinicaltrials.gov/ct2/show/record/NCT03074253

Keywords