Diagnostics (Oct 2023)

Implementation of Individualized Low-Dose Computed Tomography-Guided Hook Wire Localization of Pulmonary Nodules: Feasibility and Safety in the Clinical Setting

  • Wei Wei,
  • Shi-Geng Wang,
  • Jing-Yi Zhang,
  • Xiao-Yu Togn,
  • Bei-Bei Li,
  • Xin Fang,
  • Ren-Wang Pu,
  • Yu-Jing Zhou,
  • Yi-Jun Liu

DOI
https://doi.org/10.3390/diagnostics13203235
Journal volume & issue
Vol. 13, no. 20
p. 3235

Abstract

Read online

Background: CT-guided hook-wire localization is an essential step in the management of small pulmonary nodules. Few studies, however, have focused on reducing radiation exposure during the procedure. Purpose: This study aims to explore the feasibility of implementing a low-dose computed tomography (CT)-guided hook wire localization using tailored kVp based on patients’ body size. Materials and Methods: A total of 151 patients with small pulmonary nodules were prospectively enrolled for CT-guided hook wire localization using individualized low-dose CT (LDCT) vs. standard-dose CT (SDCT) protocols. Radiation dose, image quality, characteristics of target nodules and procedure-related variables were compared. All variables were analyzed using Chi-Square and Student’s t-test. Results: The mean CTDIvol was significantly reduced for LDCT (for BMI ≤ 21 kg/m2, 0.56 ± 0.00 mGy and for BMI > 21 kg/m2, 1.48 ± 0.00 mGy) when compared with SDCT (for BMI ≤ 21 kg/m2, 5.24 ± 0.95 mGy and for BMI > 21 kg/m2, 6.69 ± 1.47 mGy). Accordingly, the DLP of LDCT was significantly reduced as compared with that of SDCT (for BMI ≤ 21 kg/m2, 56.86 ± 4.73 vs. 533.58 ± 122.06 mGy.cm, and for BMI > 21 kg/m2, 167.02 ± 38.76 vs. 746.01 ± 230.91 mGy.cm). In comparison with SDCT, the effective dose (ED) of LDCT decreased by an average of 89.42% (for BMI ≤ 21 kg/m2) and 77.68% (for BMI > 21 kg/m2), respectively. Although the images acquired with the LDCT protocol yielded inferior quality to those acquired with the SDCT protocol, they were clinically acceptable for hook wire localization. Conclusions: LDCT-guided localization can provide safety and nodule detection performance comparable to SDCT-guided localization, benefiting radiation dose reduction dramatically, especially for patients with small body mass indexes.

Keywords