Cancers (Jun 2021)

Interfractional Geometric Variations and Dosimetric Benefits of Stereotactic MRI Guided Online Adaptive Radiotherapy (SMART) of Prostate Bed after Radical Prostatectomy: Post-Hoc Analysis of a Phase II Trial

  • Minsong Cao,
  • Yu Gao,
  • Stephanie M. Yoon,
  • Yingli Yang,
  • Ke Sheng,
  • Leslie K. Ballas,
  • Vincent Basehart,
  • Ankush Sachdeva,
  • Carol Felix,
  • Daniel A. Low,
  • Michael L. Steinberg,
  • Amar U. Kishan

DOI
https://doi.org/10.3390/cancers13112802
Journal volume & issue
Vol. 13, no. 11
p. 2802

Abstract

Read online

Purpose: To evaluate geometric variations of patients receiving stereotactic body radiotherapy (SBRT) after radical prostatectomy and the dosimetric benefits of stereotactic MRI guided adaptive radiotherapy (SMART) to compensate for these variations. Materials/Methods: The CTV and OAR were contoured on 55 MRI setup scans of 11 patients treated with an MR-LINAC and enrolled in a phase II trial of post-prostatectomy SBRT. All patients followed institutional bladder and rectum preparation protocols and received five fractions of 6−6.8 Gy to the prostate bed. Interfractional changes in volume were calculated and shape deformation was quantified by the Dice similar coefficient (DSC). Changes in CTV-V95%, bladder and rectum maximum dose, V32.5Gy and V27.5Gy were predicted by recalculating the initial plan on daily MRI. SMART was retrospectively simulated if the predicted dose exceeded pre-set criteria. Results: The CTV volume and shape remained stable with a median volumetric change of 3.0% (IQR −3.0% to 11.5%) and DSC of 0.83 (IQR 0.79 to 0.88). Relatively large volumetric changes in bladder (median −24.5%, IQR −34.6% to 14.5%) and rectum (median 5.4%, IQR − 9.7% to 20.7%) were observed while shape changes were moderate (median DSC of 0.79 and 0.73, respectively). The median CTV-V95% was 98.4% (IQR 94.9% to 99.6%) for the predicted doses. However, SMART would have been deemed beneficial for 78.2% of the 55 fractions based on target undercoverage (16.4%), exceeding OAR constraints (50.9%), or both (10.9%). Simulated SMART improved the dosimetry and met dosimetric criteria in all fractions. Moderate correlations were observed between the CTV-V95% and target DSC (R2 = 0.73) and bladder mean dose versus volumetric changes (R2 = 0.61). Conclusions: Interfractional dosimetric variations resulting from anatomic deformation are commonly encountered with post-prostatectomy RT and can be mitigated with SMART.

Keywords