BMC Pulmonary Medicine (Dec 2018)

Randomized controlled trial to evaluate the utility of suction and inner-stylet of EBUS-TBNA for mediastinal and hilar lymphadenopathy

  • Xiaoxiao Lin,
  • Min Ye,
  • Yuping Li,
  • Jing Ren,
  • Qiyan Lou,
  • Yangyang Li,
  • Xiaohui Jin,
  • Ko-Pen Wang,
  • Chengshui Chen

DOI
https://doi.org/10.1186/s12890-018-0751-0
Journal volume & issue
Vol. 18, no. 1
pp. 1 – 7

Abstract

Read online

Abstract Background The optimal procedure for maximizing the diagnostic yield and minimizing the procedural complexity of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is controversial. We conducted a prospective randomized controlled trial to determine the optimal procedure of EBUS-TBNA for mediastinal and hilar lymphadenopathy, with a particular focus on the roles of the inner-stylet and suction. Methods Consecutive patients with enlarged mediastinal and hilar lymph nodes (LNs), detected by computed tomography (CT) or positron emission tomography-CT (PET-CT), who underwent EBUS-TBNA were included. Each LN was sampled with three needle passes using suction–stylet, suction–no stylet, and stylet–no suction procedures. The samples were smeared onto glass slides for cytological evaluation. A single, blinded cytopathologist evaluated each set of slides. The primary outcomes were cytological specimen adequacy rate and diagnostic yield of malignant LNs. The secondary outcomes were tissue-core acquisition rate, procedural time, and the amount of bleeding. Results This study evaluated 97 patients with a total of 255 LNs. The final LN diagnosis was benign in 144, malignant in 104, and inadequate in 7 cases. There were no significant differences among the suction–stylet, suction–no stylet, and stylet–no suction groups in specimen adequacy rate (87.1, 88.2, 85.9%, respectively) or diagnostic yield of malignancy (32.2, 31.8, 31.0%, respectively). However, the use of suction was associated with an increase in tissue-core acquisition rate (P < 0.001). The no-stylet procedure decreased the average procedural time by 14 s (P < 0.001). There was no significant difference in the amount of bleeding among the procedures. Conclusions The use of suction or non-use of an inner-stylet does not make a significant difference in cytological specimen adequacy or diagnostic yield when performing EBUS-TBNA. While omitting the stylet can simplify the procedure, applying suction can increase the tissue-core acquisition rate. These findings may assist endoscopic physicians in determining the optimal EBUS-TBNA procedure and warrant clinical verification in a future multicentre study. Trial registration Trial registration: (ChiCTR-IOR-17010616). Retrospective registered date: 12th February, 2017.

Keywords