Journal of Applied Oral Science (Jun 2011)

Surface roughness of orthodontic band cements with different compositions

  • Françoise Hélène van de Sande,
  • Adriana Fernandes da Silva,
  • Douver Michelon,
  • Evandro Piva,
  • Maximiliano Sérgio Cenci,
  • Flávio Fernando Demarco

DOI
https://doi.org/10.1590/S1678-77572011000300008
Journal volume & issue
Vol. 19, no. 3
pp. 223 – 227

Abstract

Read online

OBJECTIVES: The present study evaluated comparatively the surface roughness of four orthodontic band cements after storage in various solutions. MATERIAL AND METHODS: Eight standardized cylinders were made from 4 materials: zinc phosphate cement (ZP), compomer (C), resin-modified glass ionomer cement (RMGIC) and resin cement (RC). Specimens were stored for 24 h in deionized water and immersed in saline (pH 7.0) or 0.1 M lactic acid solution (pH 4.0) for 15 days. Surface roughness readings were taken with a profilometer (Surfcorder SE1200) before and after the storage period. Data were analyzed by two-way ANOVA and Tukey's test (comparison among cements and storage solutions) or paired t-test (comparison before and after the storage period) at 5% significance level. RESULTS: The values for average surface roughness were statistically different (pRMGIC>C>R (p0.05). Compared to the current threshold (0.2 µm) related to biofilm accumulation, both RC and C remained below the threshold, even after acidic challenge by immersion in lactic acid solution. CONCLUSIONS: Storage time and immersion in lactic acid solution increased the surface roughness of the majority of the tested cements. RC presented the smoothest surface and it was not influenced by storage conditions.

Keywords