Science and Technology of Nuclear Installations (Jan 2022)

Coincidence Summing Factor Calculation for Volumetric γ-ray Sources Using Geant4 Simulation

  • Dalal Abdullah Aloraini,
  • Mohamed Elsafi,
  • Aljawhara H. Almuqrin,
  • M.I. Sayyed

DOI
https://doi.org/10.1155/2022/5718920
Journal volume & issue
Vol. 2022

Abstract

Read online

Geant4 simulation was applied to correct the coincidence summing (CS) effect in detecting a volumetric γ-ray sources, and this technique was applied to a152Eu standard sources. The radioactive sources were a liquid cylindrical, rectangular, and Marinelli beaker shapes of different volume for each one. Radionuclide track (RT) including coincidence summing and monoenergetic track without coincidence summing. The results obtained from two approaches compared with the experimental data and the modified KORSUM code for cylindrical γ-ray source. The comparison showed that the adopted method in this investigation is useful for coincidence summing corrections for a voluminous γ-ray sources.Moreover, this technique requires far less computation time than the techniques that depend on the calculation of total efficiency.