Journal of Craniovertebral Junction and Spine (Jan 2022)

C2/3 Transfacetal fixation: An underutilized technique of C2 fixation in the management of atlantoaxial dislocation − A technical note with review of literature

  • Deepak Kumar Singh,
  • Diwakar Shankar,
  • Rakesh Kumar Singh,
  • Mohammad Kaif,
  • Kuldeep Yadav

DOI
https://doi.org/10.4103/jcvjs.jcvjs_135_21
Journal volume & issue
Vol. 13, no. 1
pp. 4 – 8

Abstract

Read online

Background: Atlantoaxial Dislocation (AAD) is a complex disorder of craniovertebral junction (CVJ). Many techniques are available to treat AAD but there are some specific conditions where some techniques have advantage over the other. Technical Advantage: C2-3 transfacetal screw with standard C1 lateral mass fixation provides a stronger construct because of four cortices incorporation and divergent course of screws and is biomechanically comparable to other forms of C2 fixation techniques. It is a technically less demanding and time-consuming. It is also a good alternative in cases having significant osteopenia. Conclusion: C2-3 transfacetal screw with standard C1 lateral mass fixation is an effective alternative to routine C1 lateral mass and C2 pedicle/pars screw fixation in cases of atlantoaxial dislocation complicated with high riding or posteriorly placed vertebral artery and thin pedicle of C2 vertebra.

Keywords