Frontiers in Cardiovascular Medicine (Apr 2021)

Micro-CT-Based Quantification of Extracted Thrombus Burden Characteristics and Association With Angiographic Outcomes in Patients With ST-Elevation Myocardial Infarction: The QUEST-STEMI Study

  • Efstratios Karagiannidis,
  • Andreas S Papazoglou,
  • Georgios Sofidis,
  • Evangelia Chatzinikolaou,
  • Kleoniki Keklikoglou,
  • Kleoniki Keklikoglou,
  • Eleftherios Panteris,
  • Anastasios Kartas,
  • Nikolaos Stalikas,
  • Thomas Zegkos,
  • Fotios Girtovitis,
  • Dimitrios V. Moysidis,
  • Leandros Stefanopoulos,
  • Kleanthis Koupidis,
  • Stavros Hadjimiltiades,
  • George Giannakoulas,
  • Christos Arvanitidis,
  • Christos Arvanitidis,
  • James S. Michaelson,
  • Haralambos Karvounis,
  • Georgios Sianos

DOI
https://doi.org/10.3389/fcvm.2021.646064
Journal volume & issue
Vol. 8

Abstract

Read online

Background: Angiographic detection of thrombus in STEMI is associated with adverse outcomes. However, routine thrombus aspiration failed to demonstrate the anticipated benefit. Hence, management of high coronary thrombus burden remains challenging. We sought to assess for the first time extracted thrombotic material characteristics utilizing micro-computed tomography (micro-CT).Methods: One hundred thirteen STEMI patients undergoing thrombus aspiration were enrolled. Micro-CT was undertaken to quantify retrieved thrombus volume, surface, and density. Correlation of these indices with angiographic and electrocardiographic outcomes was performed.Results: Mean aspirated thrombus volume, surface, and density (±standard deviation) were 15.71 ± 20.10 mm3, 302.89 ± 692.54 mm2, and 3139.04 ± 901.88 Hounsfield units, respectively. Aspirated volume and surface were significantly higher (p < 0.001) in patients with higher angiographic thrombus burden. After multivariable analysis, independent predictors for thrombus volume were reference vessel diameter (RVD) (p = 0.011), right coronary artery (RCA) (p = 0.039), and smoking (p = 0.027), whereas RVD (p = 0.018) and RCA (p = 0.019) were predictive for thrombus surface. Thrombus volume and surface were independently associated with distal embolization (p = 0.007 and p = 0.028, respectively), no-reflow phenomenon (p = 0.002 and p = 0.006, respectively), and angiographically evident residual thrombus (p = 0.007 and p = 0.002, respectively). Higher thrombus density was correlated with worse pre-procedural TIMI flow (p < 0.001). Patients with higher aspirated volume and surface developed less ST resolution (p = 0.042 and p = 0.023, respectively).Conclusions: Angiographic outcomes linked with worse prognosis were more frequent among patients with larger extracted thrombus. Despite retrieving larger thrombus load in these patients, current thrombectomy devices fail to deal with thrombotic material adequately. Further studies of novel thrombus aspiration technologies are warranted to improve patient outcomes.Clinical Trial Registration: QUEST-STEMI trial ClinicalTrials.gov number: NCT03429608 Date of registration: February 12, 2018. The study was prospectively registered.

Keywords