BMC Anesthesiology (Jan 2022)
Slope analysis for the prediction of fluid responsiveness by a stepwise PEEP elevation recruitment maneuver in mechanically ventilated patients
Abstract
Abstract Objective Assessment of fluid responsiveness is problematic in intensive care unit patients. Lung recruitment maneuvers (LRM) can be used as a functional test to predict fluid responsiveness. We propose a new test to predict fluid responsiveness in mechanically ventilated patients by analyzing the variations in central venous pressure (CVP) and systemic arterial parameters during a prolonged sigh breath LRM without the use of a cardiac output measuring device. Design Prospective observational cohort study. Setting Intensive Care Unit, Saint-Etienne University Central Hospital. Patients Patients under mechanical ventilation, equipped with invasive arterial blood pressure, CVP, pulse contour analysis (PICCO™), requiring volume expansion, with no right ventricular dysfunction. Interventions. None. Measurements and main results CVP, systemic arterial parameters and stroke volume (SV) were recorded during prolonged LRM followed by a 500 mL fluid expansion to asses fluid responsiveness. 25 patients were screened and 18 patients analyzed. 9 patients were responders to volume expansion and 9 were not. Evaluation of hemodynamic parameters suggested the use of a linear regression model. Slopes for systolic arterial pressure, pulse pressure (PP), CVP and SV were all significantly different between responders and non-responders during the pressure increase phase of LRM (STEP-UP) (p = 0.022, p = 0.014, p = 0.006 and p = 0.038, respectively). PP and CVP slopes during STEP-UP were strongly predictive of fluid responsiveness with an AUC of 0.926 (95% CI, 0.78 to 1.00), sensitivity = 100%, specificity = 89% and an AUC = 0.901 (95% CI, 0.76 to 1.00), sensibility = 78%, specificity = 100%, respectively. Combining sensitivity of PP and specificity of CVP, prediction of fluid responsiveness can be achieved with 100% sensitivity and 100% specificity (AUC = 0.96; 95% CI, 0.90 to 1.00). One patient showed inconclusive values using the grey zone approach (5.5%). Conclusions In patients under mechanical ventilation with no right heart dysfunction, the association of PP and CVP slope analysis during a prolonged sigh breath LRM seems to offer a very promising method for prediction of fluid responsiveness without the use and associated cost of a cardiac output measurement device. Trial registration NCT04304521 , IRBN902018/CHUSTE. Registered 11 March 2020, Fluid responsiveness predicted by a stepwise PEEP elevation recruitment maneuver in mechanically ventilated patients (STEP-PEEP)
Keywords