Indian Journal of Ophthalmology (Jan 2016)

Ab-interno scleral suture loop fixation with cow-hitch knot in posterior chamber intraocular lens decentration

  • Ertugrul Can,
  • Nurullah Koçak,
  • Özlem Eski Yücel,
  • Adem Gül,
  • Hilal Eser Öztürk,
  • Osman Sayin

DOI
https://doi.org/10.4103/0301-4738.179712
Journal volume & issue
Vol. 64, no. 2
pp. 124 – 126

Abstract

Read online

Aim of Study: To describe a simplified ab-interno cow-hitch suture fixation technique for repositioning decentered posterior chamber intraocular lens (PC IOL). Materials and Methods: Two cases are presented with the surgical correction of decentered and subluxated IOL. Ab-interno scleral suture fixation technique with hitch-cow knot in the eye was performed with a ciliary sulcus guide instrument and 1 year follow-up was completed. Results: Both of the patients had well centered lenses postoperatively. Corrected distant and near visual acuities of the patients were improved. There was no significant postoperative complication. In the follow-up period of 1 year, no evidence of suture erosion was found. Conclusions: Ab-interno scleral suture loop fixation with hitch-cow knot in the eye was effective in repositioning decentered or subluxated PC IOLs with excellent postoperative centered lenses and visual outcomes.

Keywords