Vascular Specialist International (Dec 2019)

Use of Paclitaxel Eluting Stents in Arteriovenous Fistulas: A Pilot Study

  • Krystal Dinh,
  • Shannon D. Thomas,
  • Tae Cho,
  • John Swinnen,
  • Phillip Crowe,
  • Ramon L. Varcoe

DOI
https://doi.org/10.5758/vsi.2019.35.4.225
Journal volume & issue
Vol. 35, no. 4
pp. 225 – 231

Abstract

Read online

PurposeWe report short-term patency outcomes of a proof of concept study conducted to determine the efficacy of drug-eluting stent (DES) for the treatment of arteriovenous fistula (AVF) stenosis in hemodialysis patients.Materials and Methods : This is a single-center, retrospective observational study involving 10 patients with AVF dysfunction treated with DESs between January 2017 and December 2017. The primary outcome was AVF patency confirmed by sonographic and clinical assessment at 1 month and 6 to 9 months after treatment.Results : A total of 12 DESs were deployed in 10 patients with dysfunctional AVF (radiocephalic: 7, brachiocephalic: 3). During the early follow up (mean: 28.6 days), primary access circuit and DES patency was 100%, with an average volume flow rate of 886.4 mL/min. Nine patients were available for short-term follow up (mean: 202.4 days; 1 unrelated death), with a mean volume flow rate of 1,048.9 mL/min. The primary DES patency was 7/9 (77.8%), and 3 patients required angioplasty at other parts of the circuit (primary access circuit patency: 4/9 [44.4%]). The assisted primary access circuit patency was 77.8%. In 2 patients, the ultrasound revealed that the DESs were thrombosed without any antecedent stenosis; they were salvaged with angioplasty. Both patients previously underwent 2 DESs implanted and recently stopped dual antiplatelet therapy. B-mode sonographic assessment at all timepoints showed minimal intimal ingrowth on the stent struts.Conclusion : This study demonstrates acceptable short-term patency for DESs in the treatment of AVF stenosis. Dual antiplatelet therapy is probably mandatory in the short term.