Drug Design, Development and Therapy (Jun 2017)

Efficacy and safety of retinol palmitate ophthalmic solution in the treatment of dry eye: a Japanese Phase II clinical trial

  • Toshida H,
  • Funaki T,
  • Ono K,
  • Tabuchi N,
  • Watanabe S,
  • Seki T,
  • Otake H,
  • Kato T,
  • Ebihara N,
  • Murakami A

Journal volume & issue
Vol. Volume 11
pp. 1871 – 1879

Abstract

Read online

Hiroshi Toshida,1 Toshinari Funaki,2 Koichi Ono,3 Nobuhito Tabuchi,4 Sota Watanabe,4 Tamotsu Seki,5 Hiroshi Otake,6 Takuji Kato,7 Nobuyuki Ebihara,8 Akira Murakami2 1Department of Ophthalmology, Juntendo University Shizuoka Hospital, Shizuoka, 2Department of Ophthalmology, Juntendo University Graduate School of Medicine, 3Department of Ophthalmology, Juntendo Tokyo Koto Geriatric Medical Center, Tokyo, 4Pharmaceutical Research Laboratories, Lion Corporation, Kanagawa, 5Tamagawa Eye Clinic, Tokyo, 6Otake Eye Clinic, Kanagawa, 7Kato Eye Clinic, Tokyo, 8Department of Ophthalmology, Juntendo University Urayasu Hospital, Chiba, Japan Purpose: The purpose of this study was to investigate the efficacy and safety of the administration of retinol palmitate (VApal) ophthalmic solution (500 IU/mL) for the treatment of patients with dry eye. Patients and methods: This study included 66 patients with dry eye. After a 2-week washout period, patients were randomized (1:1) into either a VApal ophthalmic solution or a placebo group, and a single drop of either solution was administered six times daily for 4 weeks. Efficacy measures were 12 subjective symptoms, rose bengal (RB) and fluorescein staining scores, tear film breakup time, and tear secretion. Safety measures included clinical blood and urine analyses and adverse event recordings. Results: In comparisons of the two groups, the mean change in RB staining score from baseline was significantly lower in the VApal group at 2 and 4 weeks (P<0.05 and P<0.01, respectively). Furthermore, the fluorescein clearance rate (fluorescein staining score) was significantly higher in the VApal group at 4 weeks (P<0.05). The VApal group showed a significant improvement in blurred vision at 1 and 2 weeks (P<0.01 and P<0.05, respectively), and the mean change in the total score for subjective symptoms from baseline was significantly lower in the VApal group at 1 week (P<0.05). In before- and after-intervention comparisons, the fluorescein and RB staining scores showed improvement in both groups. Improvement was noted for 11 subjective symptoms in the VApal group and for seven symptoms in the placebo group. No significant differences in adverse events and reactions were found between the groups. Conclusion: VApal ophthalmic solution (500 IU/mL) is safe and effective for the treatment of patients with dry eye. Keywords: vitamin A, cornea, conjunctiva, tear, mucin

Keywords