Sensors (Jun 2023)

The Effects of a Simple Sensor Reorientation Procedure on Peak Tibial Accelerations during Running and Correlations with Ground Reaction Forces

  • Molly M. Bradach,
  • Logan W. Gaudette,
  • Adam S. Tenforde,
  • Jereme Outerleys,
  • José R. de Souza Júnior,
  • Caleb D. Johnson

DOI
https://doi.org/10.3390/s23136048
Journal volume & issue
Vol. 23, no. 13
p. 6048

Abstract

Read online

While some studies have found strong correlations between peak tibial accelerations (TAs) and early stance ground reaction forces (GRFs) during running, others have reported inconsistent results. One potential explanation for this is the lack of a standard orientation for the sensors used to collect TAs. Therefore, our aim was to test the effects of an established sensor reorientation method on peak Tas and their correlations with GRFs. Twenty-eight runners had TA and GRF data collected while they ran at a self-selected speed on an instrumented treadmill. Tibial accelerations were reoriented to a body-fixed frame using a simple calibration trial involving quiet standing and kicking. The results showed significant differences between raw and reoriented peak TAs (p p = 0.48). The medial and lateral peaks were higher (+0.9–1.3 g), while the vertical and anterior were lower (−0.5–1.6 g) for reoriented vs. raw accelerations. Correlations with GRF measures were generally higher for reoriented TAs, although these differences were fairly small (Δr2 = 0.04–0.07) except for lateral peaks (Δr2 = 0.18). While contingent on the position of the IMU on the tibia used in our study, our results first showed systematic differences between reoriented and raw peak accelerations. However, we did not find major improvements in correlations with GRF measures for the reorientation method. This method may still hold promise for further investigation and development, given that consistent increases in correlations were found.

Keywords