Urinary Dipstick Is Not Reliable as a Screening Tool for Albuminuria in the Emergency Department—A Prospective Cohort Study

  • Christian B. Nielsen,
  • Henrik Birn,
  • Frans Brandt,
  • Jan D. Kampmann

DOI
https://doi.org/10.3390/diagnostics12020457
Journal volume & issue
Vol. 12, no. 2
p. 457

Abstract

Read online

Albuminuria is a sensitive marker for renal dysfunction. Urinary dipstick tests are frequently used to screen for urinary abnormalities in the emergency department (ED). The aim of this prospective cohort study is to evaluate the usefulness of urinary dipstick testing as a screening tool for albuminuria in the ED setting and to determine the persistency of albuminuria identified in the acute setting. Urinary dipstick tests and spot urine samples were obtained simultaneously for analysis of the urinary albumin-creatinine ratio (ACR). Participants with positive dipsticks for protein were invited for a second urinalysis four to six weeks after admission. The study included 234 patients admitted to the ED. Urinalysis was performed on 178 patients of which 46% (n = 82) had positive urinary dipstick tests for proteinuria. The sensitivity and specificity of the dipstick test were low (72.7% and 55.7% respectively) when compared to the ACR. Of the 82 patients with positive dipsticks at admission, 35 were available for follow-up. We observed a significant reduction in ACR at follow-up when compared to ACR at admission (p = 0.004). This paper concludes that urinary dipstick tests are not a reliable means to screen for albuminuria in the ED setting.

Keywords