BMC Musculoskeletal Disorders (Apr 2024)

Survivorship of the fixed-bearing medial unicompartmental knee arthroplasty: mean 14-year follow-up in a single medical center

  • Kung-Tseng Hung,
  • Chun‑Chieh Chen,
  • Yu-Chih Lin,
  • Sheng-Hsun Lee,
  • Chih-Chien Hu,
  • Yu-Han Chang,
  • Pang-Hsin Hsieh,
  • Hsin-Nung Shih,
  • Chih-Hsiang Chang

DOI
https://doi.org/10.1186/s12891-024-07378-1
Journal volume & issue
Vol. 25, no. 1
pp. 1 – 9

Abstract

Read online

Abstract Background This study aimed to report the long-term survival of fixed-bearing medial unicompartmental knee arthroplasty (UKA) with a mean of 14-year follow-up, and to determine possible risk factors of failure. Methods We retrospectively evaluated 337 fixed-bearing medial UKAs implanted between 2003 and 2014. Demographic and radiographic parameters were measured, including pre-operative and post-operative anatomical femorotibial angle (aFTA), posterior tibial slope (PTS), and anatomical medial proximal tibial angle (aMPTA). Multivariate logistic regression analysis was applied to figure out risk factors. Results The mean follow-up time was 14.0 years. There were 32 failures categorized into implant loosening (n = 11), osteoarthritis progression (n = 7), insert wear (n = 7), infection (n = 4), and periprosthetic fracture (n = 3). Cumulative survival was 91.6% at 10 years and 90.0% at 15 years. No statistically significant parameters were found between the overall survival and failure groups. Age and hypertension were significant factors of implant loosening with odds ratio (OR) 0.909 (p = 0.02) and 0.179 (p = 0.04) respectively. In the insert wear group, post-operative aFTA and correction of PTS showed significance with OR 0.363 (p = 0.02) and 0.415 (p = 0.03) respectively. Post-operative aMPTA was a significant factor of periprosthetic fracture with OR 0.680 (p < 0.05). Conclusions The fixed-bearing medial UKA provides successful long-term survivorship. Tibial component loosening is the major cause of failure. Older age and hypertension were factors with decreased risk of implant loosening.

Keywords