Journal of Pharmacy and Bioallied Sciences (Jan 2024)
Assessment of efficacy of various bracket base retention qualities on shear bond strength
Abstract
Introduction: Numerous manufacturers have improved bracket retention systems as a result of the frequent bond failure that occurs during orthodontic treatment. One of the elements affecting the adhesive's bond strength is the bracket retention mechanism. Objectives: This study's objective was to assess how various bracket base retention characters affected shear bond strength. Materials and Methods: Four distinct base features for brackets were evaluated. The basic design was examined using a scanning electron microscope. On the Universal testing equipment, brackets were glued to human teeth and then released. Results: The findings indicate that the polymer-coated base's overall mean SBS, which had a mean value of 21.64 ± 4.14 MPa, was considerably greater than that of the other brackets (P 0.05). The foil meshpad, photochemically etched base, and laser-structured base had mean SBS values of 15.12 ± 5.75 MPa, 16.86 ± 3.76 MPa, and 19.32 ± 4.23MPa, respectively. Conclusions: Following laser-structured base and photochemically etched base brackets in terms of shear bond strength were polymer-coated base brackets. The shear bond strength was the lowest in the plain foil mesh pads.
Keywords