MATEC Web of Conferences (Jan 2022)

The design of the sampling parameters for CMM of free-form surfaces

  • Zhang Yikun,
  • Chen Yueping,
  • Huang Kaiqi

DOI
https://doi.org/10.1051/matecconf/202235503066
Journal volume & issue
Vol. 355
p. 03066

Abstract

Read online

In order to improve the inspection accuracy of free-form surface by CMM, this paper adopted the different sampling parameters to research the influence of the measurement accuracy of free-form surface. Through the combination of area uniform block random sampling and Latin hypercube random sampling, the minimum sampling grid block area and ball diameter were taken as the research parameters. Firstly, this research analysed theoretically the influence of measurement accuracy of free-form surface by different sampling parameters. Secondly, carrying out experiments verified the analytical results. Then, the influence of two groups of sampling parameters on the normal deviation of free-form surface could be acquired by analysing the experimental data. Finally, this research could obtain the result of normal deviation of free-form surface. The research results showed that the minimum block area of sampling and the diameter of measuring ball become smaller, and the profile error become larger when the number of measuring points were the same, the more it can reflect the actual contour of the free-form surface, which proves that the measurement accuracy is higher.

Keywords