Highly Sensitive Magnetic-Nanoparticle-Based Immunochromatography Assay for Rapid Detection of Amantadine in Chicken and Eggs
Huaming Li,
Yanrong Lu,
Linwei Zhang,
Liangni Qin,
Hao Wen,
Xiaohui Fan,
Dapeng Peng
Affiliations
Huaming Li
State Key Laboratory of Agricultural Microbiology, National Reference Laboratory of Veterinary Drug Residues (HZAU) and MOA Key Laboratory for Detection of Veterinary Drug Residues, Huazhong Agricultural University, Wuhan 430070, China
Yanrong Lu
State Key Laboratory of Agricultural Microbiology, National Reference Laboratory of Veterinary Drug Residues (HZAU) and MOA Key Laboratory for Detection of Veterinary Drug Residues, Huazhong Agricultural University, Wuhan 430070, China
Linwei Zhang
State Key Laboratory of Agricultural Microbiology, National Reference Laboratory of Veterinary Drug Residues (HZAU) and MOA Key Laboratory for Detection of Veterinary Drug Residues, Huazhong Agricultural University, Wuhan 430070, China
Liangni Qin
State Key Laboratory of Agricultural Microbiology, National Reference Laboratory of Veterinary Drug Residues (HZAU) and MOA Key Laboratory for Detection of Veterinary Drug Residues, Huazhong Agricultural University, Wuhan 430070, China
Hao Wen
State Key Laboratory of Agricultural Microbiology, National Reference Laboratory of Veterinary Drug Residues (HZAU) and MOA Key Laboratory for Detection of Veterinary Drug Residues, Huazhong Agricultural University, Wuhan 430070, China
Xiaohui Fan
Wuhan Shangcheng Biotechnology Co., Ltd., Wuhan 430070, China
Dapeng Peng
State Key Laboratory of Agricultural Microbiology, National Reference Laboratory of Veterinary Drug Residues (HZAU) and MOA Key Laboratory for Detection of Veterinary Drug Residues, Huazhong Agricultural University, Wuhan 430070, China
Amantadine (AMD) is an antiviral drug that is prohibited for use in livestock and poultry. In this study, carboxyl-modified magnetic nanoparticles (MNPs) were synthesized using the solvothermal method in one step with harmless and inexpensive regents, and they were used to label monoclonal antibodies (mAbs) of AMD in microwells with electrostatic adsorption. Then, a magnetic immunochromatography assay (MICA) method was successfully established. Under optimal conditions, the MICA showed a good performance, with a linear range of 0.2~10.0 µg/L. The limit of detection (LOD) was 0.068 µg/L with the instrument, and the visual LOD (vLOD) was 0.5 µg/L. There was no cross-reaction with rimantadine and ribavirin. The vLOD in real samples was 1.0 µg/kg. The developed MICA has the advantages of convenience, speed, and sensitivity, which make it suitable for the on-site rapid detection of AMD residues in chicken tissues and eggs.