Sakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi (Jun 2012)
Biomechanical Comparison Of Intact Lumbar Lamp Spine And Endoscopic Discectomized Lamp Spine
Abstract
Objectives: Purpose of current study was biomechanical comparison of changes wrought on motion segments after minimally invasive percutan endoscopic discectomized and intact spine. Materials and Methods: We prepared ten fresh-frozen lamb spines were used for this study. The spine of each specimen was dissected between L4-L5. The biomechanical tests for both intact spine and discectomized spine were performed by using axial compression testing machine (AG-I 10 kN, Shimadzu, Japanese). The axial compression was applied to all specimens with the loading speed of 5 mm/min. 8400 N/mm moment was applied to each specimen to achieve flexion and extension motions, right and left bending by a specially designed fixture. Results: In axial compression and flexion tests, the specimens were more stable according to displacement values. The displacement values of sectioned specimens were closer to intact specimens. Only displacement values of left-bending anteroposterior test for both situations were significant (0.05 ;#8805; P). Conclusion: PTED hasn't biomechanical and cilinical disadvantages. Endoscopic discectomy hadn't any disadvantages in stability. Only anterior-posterior displacement values of left bending test were statistically significant. We consider that cause of these results were due to the fact that all specimens had percutan transforaminal endoscopic discectomy (PTED) from left side.