Cerâmica (Jul 2020)

Effect of cementation on the mechanical behavior of a nanoceramic resin

  • A. D. Nogueira,
  • P. H. Corazza,
  • O. E. Pecho,
  • M. M. Perez,
  • M. Borba

DOI
https://doi.org/10.1590/0366-69132020663792886
Journal volume & issue
Vol. 66, no. 379
pp. 236 – 242

Abstract

Read online Read online

Abstract Conventional flexural strength tests of restorative materials neglect the effect of essential variables that can affect their mechanical behavior. The purpose of this study was to evaluate the effect of cementation on the mechanical behavior of a nanoceramic resin. A nanoceramic resin (LU) and a leucite-reinforced glass-ceramic (IE) were evaluated. Non-cemented specimens of the materials were produced and subjected to biaxial flexural strength test ( σ f , n = 30 ). Cemented specimens were constituted of the restorative material bonded with resin cement onto a dentin analog substrate. Cemented specimens were subjected to the monotonic compressive load test ( L f , n = 20 ). Vickers microhardness (HV) and translucency parameter (TP) of the materials were characterized. Data were analyzed using t-test (σf and TP), Mann-Whitney test (Lf and HV), and Weibull analysis (σf and Lf, α = 0 . 05). Non-cemented LU showed higher σf and Weibull modulus (m) than IE. When cemented to the substrate, LU showed higher Lf than IE; however, the m-value was similar among groups. LU showed lower HV than IE and higher TP values. Cementation influenced the mechanical behavior and failure mode of the nanoceramic resin.

Keywords