EPJ Web of Conferences (Sep 2012)

ECE for NTM control on ITER

  • Westerhof E.,
  • van den Brand H.,
  • de Baar M.R.,
  • Lopes Cardozo N.J.

DOI
https://doi.org/10.1051/epjconf/20123203004
Journal volume & issue
Vol. 32
p. 03004

Abstract

Read online

Control of Neoclassical Tearing Modes (NTMs) requires an accurate and low latency detection of the mode position. For a burning H-mode ITER plasma, simulations are conducted for both ECE detected via the equatorial port plug and along the line-of-sight of the ECCD launchers. Simulated ECE is detected using synthetic radiometers, with settings chosen to meet the required accuracy. A video bandwidth of 2 kHz is used which allows for an intermediate frequency bandwidth of BIF = 400 MHz for ECE detected via the equatorial port plug. For ECE detected via the ECCD line-of-sight, an intermediate frequency bandwidth of 1.5 GHz and 1 GHz for the 2/1 and 3/2 NTM respectively suffices for accurate location detection. For both ECE systems, the latency requirements for NTM suppression are fulfilled.