Open Physics (Dec 2017)

Field analysis & eddy current losses calculation in five-phase tubular actuator

  • Waindok Andrzej,
  • Tomczuk Bronislaw

DOI
https://doi.org/10.1515/phys-2017-0107
Journal volume & issue
Vol. 15, no. 1
pp. 897 – 901

Abstract

Read online

Field analysis including eddy currents in the magnetic core of five-phase permanent magnet tubular linear actuator (TLA) has been carried out. The eddy currents induced in the magnetic core cause the losses which have been calculated. The results from 2D finite element (FE) analysis have been compared with those from 3D calculations. The losses in the mover of the five-phase actuator are much lower than the losses in its stator. That is why the former ones can be neglected in the computer aided designing. The calculation results have been verified experimentally

Keywords