PLoS ONE (Jan 2017)

Magnification of digital hip radiographs differs between clinical workplaces.

  • Jana Hornová,
  • Pavel Růžička,
  • Maroš Hrubina,
  • Eduard Šťastný,
  • Andrea Košková,
  • Petr Fulín,
  • Jiří Gallo,
  • Matej Daniel

DOI
https://doi.org/10.1371/journal.pone.0188743
Journal volume & issue
Vol. 12, no. 11
p. e0188743

Abstract

Read online

Preoperative planning for total hip arthroplasty includes templating on anteroposterior radiographs. It is necessary to consider radiographic magnification in order to scale templates accurately. Studies dealing with hip templating report different values of radiographic magnification. It is not clear if the observed difference in magnification between the studies is caused by variability in studied groups, methodology or instrumentation. We hypothesize that there is a difference in magnification between clinical workplaces. Within this study, radiographic magnification was estimated on 337 radiographs of patients after total hip surgery from five orthopaedic departments in the Czech Republic. Magnification was determined for each patient as a ratio between diameter of implanted femoral head measured on radiogram and its true size. One-way ANOVA revealed significant differences in magnification between workplaces (F(4,332) = 132, p≤0.001). These results suggest that radiographic magnification depends on the workplace where it is taken or more precisely on radiographic device. It indicates potential limits in generalizability of results of studies dealing with preoperative planning accuracy to other institutions.