Cardiology Research and Practice (Jan 2010)

QT Measurement and Heart Rate Correction during Hypoglycemia: Is There a Bias?

  • Toke Folke Christensen,
  • Jette Randløv,
  • Leif Engmann Kristensen,
  • Ebbe Eldrup,
  • Ole Kristian Hejlesen,
  • Johannes Jan Struijk

DOI
https://doi.org/10.4061/2010/961290
Journal volume & issue
Vol. 2010

Abstract

Read online

Introduction. Several studies show that hypoglycemia causes QT interval prolongation. The aim of this study was to investigate the effect of QT measurement methodology, heart rate correction, and insulin types during hypoglycemia. Methods. Ten adult subjects with type 1 diabetes had hypoglycemia induced by intravenous injection of two insulin types in a cross-over design. QT measurements were done using the slope-intersect (SI) and manual annotation (MA) methods. Heart rate correction was done using Bazett’s (QTcB) and Fridericia’s (QTcF) formulas. Results. The SI method showed significant prolongation at hypoglycemia for QTcB (42(6) ms; P<.001) and QTcF (35(6) ms; P<.001). The MA method showed prolongation at hypoglycemia for QTcB (7(2) ms, P<.05) but not QTcF. No difference in ECG variables between the types of insulin was observed. Discussion. The method for measuring the QT interval has a significant impact on the prolongation of QT during hypoglycemia. Heart rate correction may also influence the QT during hypoglycemia while the type of insulin is insignificant. Prolongation of QTc in this study did not reach pathologic values suggesting that QTc prolongation cannot fully explain the dead-in-bed syndrome.