Radiation Oncology (Sep 2022)
Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma
Abstract
Abstract Background To compare the dosimetric profiles of volumetric modulated arc therapy (VMAT) plans using the fast-rotating O-ring linac (the Halcyon system) based on a dual-layer stacked multi-leaf collimator and helical tomotherapy (HT) for nasopharyngeal cancer (NPCa). Methods For 30 NPCa patients, three sets of RT plans were generated, under the same policy of contouring and dose constraints: HT plan; Halcyon VMAT plan with two arcs (HL2arc); and Halcyon VMAT plan with four arcs (HL4arc), respectively. The intended dose schedule was to deliver 67.2 Gy to the planning gross target volume (P-GTV) and 56.0 Gy to the planning clinical target volume (P-CTV) in 28 fractions using the simultaneously integrated boost concept. Target volumes and organ at risks dose metrics were evaluated for all plans. Normal tissue complication probabilities (NTCP) for esophagus, parotid glands, spinal cord, and brain stem were compared. Results The HT plan achieved the best dose homogeneity index for both P_GTV and P_CTV, followed by the HL4arc and L2arc plans. No significant difference in the dose conformity index (CI) for P_GTV was observed between the HT plan (0.80) and either the HL2arc plan (0.79) or the HL4arc plan (0.83). The HL4arc plan showed the best CI for P_CTV (0.88), followed by the HL2arc plan (0.83) and the HT plan (0.80). The HL4arc plan (median, interquartile rage (Q1, Q3): 25.36 (22.22, 26.89) Gy) showed the lowest Dmean in the parotid glands, followed by the HT (25.88 (23.87, 27.87) Gy) and HL2arc plans (28.00 (23.24, 33.99) Gy). In the oral cavity (OC) dose comparison, the HT (22.03 (19.79, 24.85) Gy) plan showed the lowest Dmean compared to the HL2arc (23.96 (20.84, 28.02) Gy) and HL4arc (24.14 (20.17, 27.53) Gy) plans. Intermediate and low dose regions (40–65% of the prescribed dose) were well fit to the target volume in HL4arc, compared to the HT and HL2arc plans. All plans met the dose constraints for the other OARs with sufficient dose margins. The between-group differences in the median NTCP values for the parotid glands and OC were < 3.47% and < 1.7% points, respectively. Conclusions The dosimetric profiles of Halcyon VMAT plans were comparable to that of HT, and HL4arc showed better dosimetric profiles than HL2arc for NPCa.
Keywords