Coluna/Columna (Sep 2021)

ESTIMATED EXPOSURE OF SPINE SURGEONS TO RADIATION

  • CARLOS ALEXANDRE BOTELHO DO AMARAL,
  • RICARDO ALVES ANDRADE,
  • PEDRO JOSÉ LABRONICI

DOI
https://doi.org/10.1590/s1808-185120212003235324
Journal volume & issue
Vol. 20, no. 3
pp. 181 – 184

Abstract

Read online

ABSTRACT Objective To estimate the amount of radiation received and accumulated in the bodies of two surgeons, one being the responsible surgeon and the other the assistant, performing spine surgery procedures over a period of 25 years. Methods Seventy-two spinal surgeries were performed during a seven-month period and the radiation loads were measured in both surgeons. The measurement of radiation was captured in fluoroscopy in anteroposterior and lateral incidences. The surgeon and the assistant used two dosimeters, one in the cervical region protecting the thyroid and the other on the lead apron in the genital region. The radioactive loads were measured in millisieverts and the accumulated charges were recorded monthly in both regions of the body in the two surgeons for seven months and the means for the work periods (1, 5, 10, 15, 20 and 25 years) were estimated. Results It was observed that in the surgeon the average accumulated radiation loads were 131.9% and 176.92% higher than those of the assistant in the cervical and genital regions, respectively. Conclusion While the use of X-rays is indispensable in routine orthopedic surgery, we have to consider the development of techniques of protection, rigor and discipline in the use of safety materials for surgeons. Preventive exposure reduction measures such as using thyroid protection equipment and turning the head away from the patient during fluoroscopy, among others, should be mandatory to promote less radiation exposure. Level of evidence II; Comparative prospective study.

Keywords