BMC Cancer (Jun 2007)

Reliability and validity of needle biopsy evaluation of breast-abnormalities using the B-categorization – design and objectives of the Diagnosis Optimisation Study (DIOS)

  • Schmidt-Pokrzywniak Andrea,
  • Loening Thomas,
  • Decker Thomas,
  • Boecker Werner,
  • Hauptmann Steffen,
  • Taege Christiane,
  • Holzhausen Hans-Juergen,
  • Heinig Anke,
  • Trocchi Pietro,
  • Kluttig Alexander,
  • Thomssen Christoph,
  • Lantzsch Tilmann,
  • Buchmann Joerg,
  • Stang Andreas

DOI
https://doi.org/10.1186/1471-2407-7-100
Journal volume & issue
Vol. 7, no. 1
p. 100

Abstract

Read online

Abstract Background The planned nationwide implementation of mammography screening 2007 in Germany will increase the occurrence of mammographically detected breast abnormalities. These abnormalities are normally evaluated by minimal invasive core biopsy. To minimize false positive and false negative histological findings, quality assurance of the pathological evaluation of the biopsies is essential. Various guidelines for quality assurance in breast cancer diagnosis recommend applying the B-classification for histopathological categorization. However, to date there are only few studies that reported results about reliability and validity of B-classification. Therefore, objectives of our study are to determine the inter- and intraobserver variability (reliability study) and construct and predictive validity (validity study) of core biopsy evaluation of breast abnormalities. This paper describes the design and objectives of the DIOS Study. Methods/Design All consecutive asymptomatic and symptomatic women with breast imaging abnormalities who are referred to the University Hospital of Halle for core breast biopsy over a period of 24 months are eligible. According to the sample size calculation we need 800 women for the study. All patients in the study population underwent clinical and radiological examination. Core biopsy is performed by stereotactic-, ultrasound- or magnetic resonance (MR) guided automated gun method or vacuum assisted method. The histopathologic agreement (intra- and interobserver) of pathologists and the histopathologic validity will be evaluated. Two reference standards are implemented, a reference pathologist and in case of suspicious or malignant findings the histopathologic result of excision biopsy. Furthermore, a self administrated questionnaire which contains questions about potential risk factors of breast cancer, is sent to the participants approximately two weeks after core biopsy. This enables us to run a case-control-analysis (woman with breast cancer histological verified after excision are defined as cases, woman without malignant breast lesions are defined as controls) to investigate the predictive values of various risk factors on breast cancer risk. Conclusion The analysis of reliability and validity of the histopathological evaluation of core biopsy specimens of breast abnormalities is intended to provide important information needed for a high quality in breast cancer diagnostic and for planning of treatment strategies.