Sensors (Oct 2024)
Research on the NI-MLA Method for Enhancing the Spot Position Detection Accuracy of Quadrant Detectors Under Atmospheric Turbulence
Abstract
The distorted spots induced by atmospheric turbulence significantly degrade the spot position detection accuracy of the quadrant detector (QD). In this paper, we utilize angular measurement and homogenization characteristics of non-imaging microlens array (NI-MLA) systems, effectively reducing the distortion degree of the spots received on the QD target surface, thereby significantly enhancing the spot detection accuracy of the QD. First, based on the principles of geometric optics and Fourier optics, it is proved that the NI-MLA system possesses the angular measurement characteristic (AMC) within the paraxial region while deriving and verifying the focal length of the system. Then, the QD computation curve characteristics of the system under non-turbulence are explored. This study further elucidates the mathematical principle of the NI-MLA system for mitigating the spot position detection random error of QD (SPDRE-QD) and discusses in depth the relationship between the NI-MLA system’s capability to mitigate the SPDRE-QD and the system’s parameters under various turbulence intensities. Finally, it is experimentally verified that the root-mean-square error (RMSE) of the QD computation values using the NI-MLA system are reduced by a significant improvement of at least 2.44 times and up to 17.36 times compared with that of the conventional optical system of QD (COS-QD) under turbulence conditions ranging from weak to strong.
Keywords