Antarctic Record (Jun 2008)

Air temperature and relative humidity in Dome Fuji Station buildings, East Antarctic ice sheet, in 2003

  • Takao Kameda,
  • Kenji Taniguchi,
  • Kyo Takahashi,
  • Takashi Kurisaki

DOI
https://doi.org/10.15094/00009445
Journal volume & issue
Vol. 52, no. special issue
pp. 193 – 203

Abstract

Read online

In order to clarify the living condition in Dome Fuji Station in 2003, air temperature and relative humidity in the station were measured. Thermocouples with data logger and a ventilated psychrometer were used for the measurements. Average air temperature from February 11, 2003 to January 14, 2004 (missing period: July 19 to August 17) in the Dome Fuji Station buildings were as follows: Generator room 24.7℃, Dining room 23.5℃, Observation room 21.1℃, Dormitory room 18.2℃, Corridor 18.2℃, Food storage 8.2℃ and Old ice coring site -51.3℃. Average outside air temperature (1.5m height from the snow surface) during the period was -54.4℃. A remarkable increase of outside air temperature (+30℃ at maximum) due to a blocking high event was observed from October 31, 2003 to November 10, 2003 at Dome Fuji, during which increase of air temperature from 5 to 8°C in the station buildings was recorded. Snow on the station buildings was partly melted and some of the melted water penetrated into the station. This was the only time snow melted during the wintering over party's stay at the station. Average relative humidity in the station buildings obtained using a small humidifier was about 25%; the relative humidity without using the humidifier ranged from 9.0 to 22.9%.