Beyoglu Eye Journal (Apr 2019)

Refractive Results and Endothelial Cell Density After Eyecryl Phakic Intraocular Lens Implantation

  • Ufuk Urdem,
  • Alper Agca

DOI
https://doi.org/10.14744/bej.2019.52824
Journal volume & issue
Vol. 4, no. 1
pp. 17 – 22

Abstract

Read online

INTRODUCTION[|]This study was an examination of the refractive results and complications encountered with implantation of the Eyecryl phakic intraocular lens (IOL) (Biotech Vision Care, Luzern, Switzerland).[¤]METHODS[|]IOL recipients with a follow-up period of at least 2 years were included the study. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively), central endothelial cell density (ECD), and procedure-related complication data were recorded.[¤]RESULTS[|]The study included 52 eyes from 26 patients. The efficacy index (postoperative UDVA/preoperative CDVA) was 1.32+-1.09 in the first year and 1.39+-1.03 in the second year. The safety index (postoperative CDVA/preoperative CDVA) was 1.69+-1.16 at the last follow-up. None of the patients lost 2 or more lines of CDVA. The mean ECD loss was –4.51+-9.69% at 1 year (p=0.005). There was no statistically significant ECD loss between the 1- and 2-year follow-up visits (p=0.794).[¤]DISCUSSION AND CONCLUSION[|]The results of Eyecryl phakic IOL implantation were favorable in terms of efficacy and safety.[¤]

Keywords