Buildings (Jun 2024)

Evaluation of Heating Time on Vacuum Preloading Treatment

  • Chaozhou Zhang,
  • Qionghui Lou,
  • Xiaoliang Wang,
  • Yuanjie Gong,
  • Xiaobing Li,
  • Hongtao Fu

DOI
https://doi.org/10.3390/buildings14061860
Journal volume & issue
Vol. 14, no. 6
p. 1860

Abstract

Read online

A comparative study of the effect of a vacuum preloading combined intermittent heating method and conventional vacuum preloading treatment was designed and carried out through indoor model tests to investigate the optimal intermittent heating time. It is concluded that the mechanism of vacuum preloading combined with the intermittent heating method is to improve the permeability of soil to alleviate the clogging effect, and therefore has a treatment effect far beyond the conventional vacuum preloading method. The results also show that setting a heating time of 120 min and a stopping time of 60 min can obtain the best consolidation effect.

Keywords