Разработка и регистрация лекарственных средств (Jan 2019)
DEVELOPMENT AND VALIDATION OF MOXIFLOXACIN DETERMINATION IN HUMAN PLASMA BY HPLC-UV METHOD
Abstract
A new method for determination of moxifloxacin in human plasma using HPLC with UV-detection is described. The sample preparation was made by protein precipitation by 50% trifluoracetic acid solution. The method was validated in terms of selectivity, calibration curve, accuracy, precision, lower limit of quantification, carry-over and stability. The analytical range was 100-5000 ng/mL. Limit of determination was 31 ng/mL. Method could be applied to moxifloxacin determination in plasma for PK and BE studies.