Critical Care (Jan 2023)

Electric impedance tomography-guided PEEP titration reduces mechanical power in ARDS: a randomized crossover pilot trial

  • Jose Victor Jimenez,
  • Elizabeth Munroe,
  • Andrew J. Weirauch,
  • Kelly Fiorino,
  • Christopher A. Culter,
  • Kristine Nelson,
  • Wassim W. Labaki,
  • Philip J. Choi,
  • Ivan Co,
  • Theodore J. Standiford,
  • Hallie C. Prescott,
  • Robert C. Hyzy

DOI
https://doi.org/10.1186/s13054-023-04315-x
Journal volume & issue
Vol. 27, no. 1
pp. 1 – 7

Abstract

Read online

Abstract Background In patients with acute respiratory distress syndrome undergoing mechanical ventilation, positive end-expiratory pressure (PEEP) can lead to recruitment or overdistension. Current strategies utilized for PEEP titration do not permit the distinction. Electric impedance tomography (EIT) detects and quantifies the presence of both collapse and overdistension. We investigated whether using EIT-guided PEEP titration leads to decreased mechanical power compared to high-PEEP/FiO2 tables. Methods A single-center, randomized crossover pilot trial comparing EIT-guided PEEP selection versus PEEP selection using the High-PEEP/FiO2 table in patients with moderate–severe acute respiratory distress syndrome. The primary outcome was the change in mechanical power after each PEEP selection strategy. Secondary outcomes included changes in the 4 × driving pressure + respiratory rate (4 ΔP, + RR index) index, driving pressure, plateau pressure, PaO2/FiO2 ratio, and static compliance. Results EIT was consistently associated with a decrease in mechanical power compared to PEEP/FiO2 tables (mean difference − 4.36 J/min, 95% CI − 6.7, − 1.95, p = 0.002) and led to lower values in the 4ΔP + RR index (− 11.42 J/min, 95% CI − 19.01, − 3.82, p = 0.007) mainly driven by a decrease in the elastic–dynamic power (− 1.61 J/min, − 2.99, − 0.22, p = 0.027). The elastic–static and resistive powers were unchanged. Similarly, EIT led to a statistically significant change in set PEEP (− 2 cmH2O, p = 0.046), driving pressure, (− 2.92 cmH2O, p = 0.003), peak pressure (− 6.25 cmH2O, p = 0.003), plateau pressure (− 4.53 cmH2O, p = 0.006), and static respiratory system compliance (+ 7.93 ml/cmH2O, p = 0.008). Conclusions In patients with moderate–severe acute respiratory distress syndrome, EIT-guided PEEP titration reduces mechanical power mainly through a reduction in elastic–dynamic power. Trial registration This trial was prospectively registered on Clinicaltrials.gov (NCT 03793842) on January 4th, 2019.

Keywords