Química Nova (Jan 2010)
Determinação de citrato de sildenafila e de tadalafila por cromatografia líquida de ultraeficiência com detecção por arranjo de diodos (CLUE-DAD) Determination of sildenafil citrate and tadalafil by ultra performance liquid chromatography with diode-array detection (UPLC-DAD)
Abstract
A simple ultra-performance liquid chromatographic method for the simultaneous determination of sildenafil citrate and tadalafil was developed and validated. Sample preparation was dissolution in methanol, followed by centrifugation and dilution (1:10) with methanol. Analysis was performed in an Acquity® UPLC system with Acquity® BEH C18 column (2.1 x 50 mm, with 1.7 μm particles). The elution was isocratic with phosphate buffer pH 2.3 and acetonitrile (65:35, v/v) at a flow rate of 0.7 mL/min. The method presented adequate specificity, linearity, precision and accuracy and allowed the determination of the drugs in seized forensic samples.
Keywords