Journal of Bone and Joint Infection (Mar 2022)

The presence of a draining sinus is associated with failure of re-implantation during two-stage exchange arthroplasty

  • A. S. ​. Gabrielli,
  • A. E. Wilson,
  • R. A. Wawrose,
  • M. Dombrowski,
  • M. J. O'Malley,
  • B. A. Klatt

DOI
https://doi.org/10.5194/jbji-7-55-2022
Journal volume & issue
Vol. 7
pp. 55 – 60

Abstract

Read online

Background: Reinfection rates after two-stage exchange arthroplasty for prosthetic joint infection (PJI) have been reported as high as 33 % in the literature. Understanding risk factors for treatment failure will help to preoperatively counsel patients on the likelihood of successful treatment and possibly influence the surgeon's treatment algorithm. This study aimed to delineate whether the presence of a draining sinus tract is associated with risk of failure of two-stage exchange arthroplasty. Methods: We performed a single institution, multi-center retrospective chart review of outcomes of patients treated for PJI with two-stage exchange arthroplasty between June 2006 and May 2016. For patients treated prior to 2011, PJI was defined based on the preoperative work-up and intraoperative findings as determined by the attending surgeon. After 2011, PJI was defined using MSIS consensus criteria. All patients had a minimum of follow-up of 2 years or treatment failure prior to 2 years. Treatment failure was defined as reinfection or failure to complete two-stage exchange secondary to persistent infection or other host factors. Operative reports and clinical notes were reviewed to assess for presence of a draining sinus tract. Results: 240 patients were treated for PJI with intended two-stage exchange arthroplasty. The overall rate of treatment failure was 29.6 % (71/240), while the overall rate of reinfection was 13.3 % (32/240). A total of 39 patients did not complete second stage revision; final treatment for these patients was amputation, fusion, or chronic antibiotic suppression. A total of 52 of 240 patients (21.7 %) had a draining sinus tract at presentation. Patients with a sinus tract were significantly less likely to be replanted compared to those without a sinus tract at presentation (13.3 % vs. 26.9 %, p=0.02). However, when accounting for all mechanisms of treatment failure, including reinfection following replantation, there was no statistically significant difference detected between the sinus and no-sinus groups (27.7 % vs. 36.5 %, p=0.22). Discussion: A draining sinus tract represents a chronic, deep infectious process with ultimate compromise of overlying soft tissues. Thus we hypothesized it would be associated with failure in a two-stage exchange arthroplasty. These data demonstrate that patients with a draining sinus are significantly less likely to undergo re-implantation. This provides evidence to the paucity of data surrounding draining sinuses and two-stage PJI treatment.