Abstract

Read online

Introduction. An ideal endodontic sealer should adhere firmly both to dentin and to gutta-percha. Objective. The aim of this study was to evaluate the adhesion of the root canal filling to dentin and gutta-percha using scanning electronic microscopy (SEM). Methods. The sealing ability of endodontic sealers to dentinal walls of the root canal was assessed in recently extracted human single canal premolars. Twenty teeth were prepared using the crown-down technique and irrigated with 3% NaOCl. A total of 20 samples were divided into two groups. The root canals were obturated using Ketac-Endo Aplicap and GutaFlow. The sealing ability and adhesion properties at the sealer-dentin interface were studied using SEM and the results were rated from 1 to 3; extremely good adhesion (rated 1), good adhesion (rated 2) and a relatively good adhesion (rated 3). Results. The results showed extremely good adhesion on Ketac-Endo and GuttaFlow dentin interface. GuttaFlow has strong adhesion (rated 1) to gutta-percha in comparison with Ketac-Endo to gutta-percha interface (rated 2). Conclusion. New GuttaFlow filling material has a strong sealing ability and excellent adhesion to dentinal walls and gutta-percha cones. Ketac-Endo showed excellent bond to dentin with a slightly weaker adhesion capacity to the gutta-percha cones in comparison to GuttaFlow.