Batteries (May 2019)

A Post-Mortem Study of Stacked 16 Ah Graphite//LiFePO<sub>4</sub> Pouch Cells Cycled at 5 °C

  • Arianna Moretti,
  • Diogo Vieira Carvalho,
  • Niloofar Ehteshami,
  • Elie Paillard,
  • Willy Porcher,
  • David Brun-Buisson,
  • Jean-Baptiste Ducros,
  • Iratxe de Meatza,
  • Aitor Eguia-Barrio,
  • Khiem Trad,
  • Stefano Passerini

DOI
https://doi.org/10.3390/batteries5020045
Journal volume & issue
Vol. 5, no. 2
p. 45

Abstract

Read online

Herein, the post-mortem study on 16 Ah graphite//LiFePO4 pouch cells is reported. Aiming to understand their failure mechanism, taking place when cycling at low temperature, the analysis of the cell components taken from different portions of the stacks and from different positions in the electrodes, is performed by scanning electron microscopy (SEM), X-ray diffraction (XRD) and X-ray photoemission spectroscopy (XPS). Also, the recovered electrodes are used to reassemble half-cells for further cycle tests. The combination of the several techniques detects an inhomogeneous ageing of the electrodes along the stack and from the center to the edge of the electrode, most probably due to differences in the pressure experienced by the electrodes. Interestingly, XPS reveals that more electrolyte decomposition took place at the edge of the electrodes and at the outer part of the cell stack independently of the ageing conditions. Finally, the use of high cycling currents buffers the low temperature detrimental effects, resulting in longer cycle life and less inhomogeneities.

Keywords