MATEC Web of Conferences (Jan 2018)
Failure Analysis of Cathode Materials for Energy Storage Batteries in Overcharge Test
Abstract
The micro-analysis of energy storage batteries in overcharge test at 20°C temperature was investigated. The results showed as follows: (1) Compared with the normal battery charge at room temperature scanning microscope maps of battery overcharge, the crystal was fractured of the positive surface when the battery was overcharging, and with the increase of experimental time, the crystal fracture is more serious, this is to say that the battery electrolyte decomposition or battery material structure could change by overcharge test. (2) Based on the XRD maps, the characteristic peak position of overcharge test of cathode materials were changed, this showed that the content of cathode material elemental has been destroyed and changed in overcharge test.