Annals of Intensive Care (Mar 2022)

SSEP N20 and P25 amplitudes predict poor and good neurologic outcomes after cardiac arrest

  • Sarah Benghanem,
  • Lee S. Nguyen,
  • Martine Gavaret,
  • Jean-Paul Mira,
  • Frédéric Pène,
  • Julien Charpentier,
  • Angela Marchi,
  • Alain Cariou

DOI
https://doi.org/10.1186/s13613-022-00999-6
Journal volume & issue
Vol. 12, no. 1
pp. 1 – 11

Abstract

Read online

Abstract Background To assess in comatose patients after cardiac arrest (CA) if amplitudes of two somatosensory evoked potentials (SSEP) responses, namely, N20-baseline (N20-b) and N20–P25, are predictive of neurological outcome. Methods Monocentric prospective study in a tertiary cardiac center between Nov 2019 and July-2021. All patients comatose at 72 h after CA with at least one SSEP recorded were included. The N20-b and N20–P25 amplitudes were automatically measured in microvolts (µV), along with other recommended prognostic markers (status myoclonus, neuron-specific enolase levels at 2 and 3 days, and EEG pattern). We assessed the predictive value of SSEP for neurologic outcome using the best Cerebral Performance Categories (CPC1 or 2 as good outcome) at 3 months (main endpoint) and 6 months (secondary endpoint). Specificity and sensitivity of different thresholds of SSEP amplitudes, alone or in combination with other prognostic markers, were calculated. Results Among 82 patients, a poor outcome (CPC 3–5) was observed in 78% of patients at 3 months. The median time to SSEP recording was 3(2–4) days after CA, with a pattern “bilaterally absent” in 19 patients, “unilaterally present” in 4, and “bilaterally present” in 59 patients. The median N20-b amplitudes were different between patients with poor and good outcomes, i.e., 0.93 [0–2.05]µV vs. 1.56 [1.24–2.75]µV, respectively (p 2 µV predicted good outcome with a specificity of 73% and a moderate sensitivity of 39%, although an N20–P25 > 3.2 µV was 93% specific and only 30% sensitive. A low voltage N20-b < 0.88 µV and N20–P25 < 1 µV predicted poor outcome with a high specificity (sp = 94% and 93%, respectively) and a moderate sensitivity (se = 50% and 66%). Association of “bilaterally absent or low voltage SSEP” patterns increased the sensitivity significantly as compared to “bilaterally absent” SSEP alone (se = 58 vs. 30%, p = 0.002) for prediction of poor outcome. Conclusion In comatose patient after CA, both N20-b and N20–P25 amplitudes could predict both good and poor outcomes with high specificity but low to moderate sensitivity. Our results suggest that caution is needed regarding SSEP amplitudes in clinical routine, and that these indicators should be used in a multimodal approach for prognostication after cardiac arrest.

Keywords